HeatPumpSwitch › By house type
Heat pump running costs by house type
Thirty worked examples. Each one has its own heat demand per square metre, its own assumed design flow temperature and therefore its own SCOP — because a 1930s solid-wall semi and a 2015 detached are not the same problem with a different label.
semi-detached house
| Era | Area | Heat | Flow | SCOP | Gas boiler now | Heat pump |
|---|---|---|---|---|---|---|
| pre-1919 | 95 m² | 18,900 kWh | 55 °C | 2.8 | £2,091 | £1,971 |
| 1976-1990 | 95 m² | 12,725 kWh | 45 °C | 3.4 | £1,452 | £1,186 |
| 1919-1944 | 95 m² | 17,475 kWh | 55 °C | 2.8 | £1,957 | £1,838 |
| 1945-1966 | 95 m² | 16,050 kWh | 50 °C | 3.0 | £1,785 | £1,606 |
| 1967-1975 | 95 m² | 14,625 kWh | 50 °C | 3.0 | £1,655 | £1,482 |
| 1991-2002 | 95 m² | 10,825 kWh | 45 °C | 3.4 | £1,216 | £1,040 |
| 2003-2011 | 95 m² | 8,925 kWh | 40 °C | 3.6 | £1,042 | £856 |
| 2012 onwards | 95 m² | 6,550 kWh | 35 °C | 3.9 | £837 | £647 |
terraced house
| Era | Area | Heat | Flow | SCOP | Gas boiler now | Heat pump |
|---|---|---|---|---|---|---|
| pre-1919 | 85 m² | 14,805 kWh | 55 °C | 2.8 | £1,706 | £1,589 |
| 1976-1990 | 85 m² | 10,109 kWh | 45 °C | 3.4 | £1,218 | £985 |
| 1919-1944 | 85 m² | 13,721 kWh | 55 °C | 2.8 | £1,604 | £1,488 |
| 1945-1966 | 85 m² | 12,638 kWh | 50 °C | 3.0 | £1,473 | £1,309 |
| 1967-1975 | 85 m² | 11,554 kWh | 50 °C | 3.0 | £1,373 | £1,214 |
| 1991-2002 | 85 m² | 8,664 kWh | 45 °C | 3.4 | £1,036 | £874 |
| 2003-2011 | 85 m² | 7,219 kWh | 40 °C | 3.6 | £903 | £732 |
| 2012 onwards | 85 m² | 5,412 kWh | 35 °C | 3.9 | £746 | £571 |
detached house
| Era | Area | Heat | Flow | SCOP | Gas boiler now | Heat pump |
|---|---|---|---|---|---|---|
| pre-1919 | 140 m² | 32,440 kWh | 55 °C | 2.8 | £3,363 | £3,234 |
| 1976-1990 | 140 m² | 21,520 kWh | 45 °C | 3.4 | £2,238 | £1,861 |
| 1919-1944 | 140 m² | 29,920 kWh | 55 °C | 2.8 | £3,126 | £2,999 |
| 1945-1966 | 140 m² | 27,400 kWh | 50 °C | 3.0 | £2,825 | £2,593 |
| 1967-1975 | 140 m² | 24,880 kWh | 50 °C | 3.0 | £2,594 | £2,374 |
| 1991-2002 | 140 m² | 18,160 kWh | 45 °C | 3.4 | £1,827 | £1,603 |
| 2003-2011 | 140 m² | 14,800 kWh | 40 °C | 3.6 | £1,520 | £1,282 |
| 2012 onwards | 140 m² | 10,600 kWh | 35 °C | 3.9 | £1,159 | £918 |
bungalow
| Era | Area | Heat | Flow | SCOP | Gas boiler now | Heat pump |
|---|---|---|---|---|---|---|
| pre-1919 | 90 m² | 20,430 kWh | 55 °C | 2.8 | £2,235 | £2,114 |
| 1976-1990 | 90 m² | 13,702 kWh | 45 °C | 3.4 | £1,540 | £1,261 |
| 1919-1944 | 90 m² | 18,877 kWh | 55 °C | 2.8 | £2,089 | £1,969 |
| 1945-1966 | 90 m² | 17,325 kWh | 50 °C | 3.0 | £1,902 | £1,717 |
| 1967-1975 | 90 m² | 15,772 kWh | 50 °C | 3.0 | £1,760 | £1,581 |
| 1991-2002 | 90 m² | 11,632 kWh | 45 °C | 3.4 | £1,284 | £1,102 |